Skip to Main Content

Find COVID-19 Information and Resources

Pipe Culverts and Endwalls

Revised: November 17, 2020
PIPE CULVERTS AND FLUME
DRAWING REVISION DATE DESCRIPTION
D-FLU-1
06/28/2019
FLUME DETAILS
D-PB-1
06/28/2019
STANDARD DETAILS FOR CONCRETE PIPE INSTALLATION
D-PB-2
06/28/2019
STANDARD DETAILS FOR FLEXIBLE PIPE INSTALLATION
D-PB-3
06/28/2019
INDUCED TRENCH SOIL EMBANKMENT FOR PIPE CULVERT INSTALLATION
D-PG-3
06/28/2019
FERROUS AND ALUMINUM CORRUGATED METAL PIPE
D-PG-4
06/28/2019
FERROUS AND ALUMINUM CORR. METAL PIPE ARCHES
D-PO-1
06/28/2019
STANDARD OVAL AND REINFORCED CONCRETE ARCH PIPE CULVERT
D-PS-1
06/28/2019
STRUTTING DETAILS FOR CORR. METAL & STRUCTURAL PLATE ROUND PIPE
     

SAFETY CROSS DRAIN ENDWALLS
DRAWING REVISION DATE DESCRIPTION
D-PE-15A
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 15" PIPE (FOR 3:1, 4:1 & 6:1 SLOPES)
D-PE-15B
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 15" PIPE, BILL OF STEEL AND PRECAST NOTES
D-PE-18A
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 18" PIPE (FOR 3:1, 4:1 & 6:1 SLOPES)
D-PE-18B
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 18" PIPE, BILL OF STEEL AND PRECAST NOTES
D-PE-24A
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 24" PIPE (FOR 3:1, 4:1 & 6:1 SLOPES)
D-PE-24B
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 24" PIPE, BILL OF STEEL AND PRECAST NOTES
D-PE-30A
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 30" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES)
D-PE-30B
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 30" PIPE, BILL OF STEEL AND PRECAST NOTES
D-PE-36A
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 36" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES)
D-PE-36B
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 36" PIPE, BILL OF STEEL AND PRECAST NOTES
D-PE-42A
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 42" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES)
D-PE-42B
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 42" PIPE, BILL OF STEEL AND PRECAST NOTES
D-PE-48A
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 48" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES)
D-PE-48B
06/28/2019
TYPE "U" CROSS DRAIN ENDWALL FOR 48" PIPE, BILL OF STEEL AND PRECAST NOTES
D-PE-99
06/28/2019
 
TYPE "U" CROSS DRAIN ENDWALL DETAILS, PIPE GRATE & SKEWED CONNECTION
     

SAFETY SIDE DRAIN ENDWALLS
DRAWING REVISION DATE DESCRIPTION
D-SEW-1A
10/16/2020
TYPE "SAFETY" SIDE DRAIN ENDWALL WITH STEEL PIPE GRATE, FOR 15" THRU 48" PIPES, 6:1 SLOPE
D-SEW-12D
10/16/2020
TYPE "SAFETY" SIDE DRAIN ENDWALL WITH STEEL PIPE GRATE, FOR 18" PIPES, 12:1 SLOPE
SD-MSE-1 06/28/2019 SIDE DRAIN MITERED END SECTION
     

PROTECTED ENDWALLS*
DRAWING REVISION DATE DESCRIPTION
D-PE-1
06/28/2019
TYPE "A" CONCRETE ENDWALLS FOR ROUND PIPE (PIPE SIZES 36" TO 78", ALL SKEWS, 2:1 SLOPE)
D-PE-4
06/28/2019
STRAIGHT CONCRETE ENDWALLS (PIPE SIZES 18" TO 30")
D-PE-5
06/28/2019
STRAIGHT CONCRETE ENDWALLS FOR HORIZONTAL OVAL CONCRETE PIPES (ALL SIZES AND SKEWS)
D-PE-8
06/28/2019
RIP-RAP END TREATMENT FOR CORRUGATED METAL PIPE, OVAL AND PIPE ARCH CULVERTS WITH BEVELED ENDS (PIPE SIZES 42" & LARGER)
D-PE-9
06/28/2019
TYPE "B" CONCRETE ENDWALLS FOR ROUND AND SIDE TAPERED INLETS (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 AND 4:1 SLOPES)
D-PE-9A
06/28/2019
TYPE "B" CONCRETE ENDWALLS FOR ROUND INLETS, DETAILS & QUANTITIES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 AND 4:1 SLOPES)
D-PE-9B
06/28/2019
TYPE "B" CONCRETE ENDWALLS FOR SIDE TAPER INLETS, DETAILS & QUANTITIES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 AND 4:1 SLOPES)
D-PE-9C
06/28/2019
TYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR CONCRETE PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 SLOPE)
D-PE-9D
06/28/2019
TYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR CONCRETE PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 4:1 SLOPE)
D-PE-9E
06/28/2019
TYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR STEEL PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 SLOPE)
D-PE-9F
06/28/2019
TYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR STEEL PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 4:1 SLOPE)
     

*NOTE: THE PROTECTED ENDWALLS MAY NOT BE USED INSIDE THE CLEAR ZONE UNLESS SHIELDED BY GUARDRAIL OR OTHER SAFETY DEVICE.

If you find any mistakes, missing information or have a question, contact:
TDOT CADD Support
1200 James K. Polk Building
Nashville, TN 37243-1402
TDOT.CADDSupport@tn.gov