Trichomonas vaginalis by NAAT
| TEST NAME |
Trichomonas vaginalis by Nucleic Acid Amplification (NAAT) |
| DISEASE/DISORDER |
Trichomonas vaginalis |
| ALTERNATE NAME(S) |
TV |
| METHODOLOGY |
Aptima Trichomonas vaginalis assay by nucleic acid amplification (NAAT) using the Hologic Panther System |
| SPECIAL INSTRUCTIONS |
- Submissions only accepted from the HIV clinics with prior authorization from CEDEP and Division of Laboratory Services.
- Testing not approved for patients <14 years of age.
|
ORDERING INFORMATION
|
Lab Web Portal
PTBMIS:
Test Order Code: TRICHV
Test Order Description: TRICHOMONAS VAGINALIS VAGINAL
|
| Specimen Requirements |
| Patient Preparation |
- Refer to manufacturer instructions provided with collection kits for specific patient preparation information.
- Only clinician-collected endocervical and vaginal swab specimens will be accepted for testing.
|
| Specimen Collection |
- Acceptable specimen types:
- Endocervical swab specimens collected with Aptima Unisex Swab Specimen Collection Kit.
- Vaginal swab specimens collected with Aptima Multitest Swab Specimen Collection Kit.
- Refer to manufacturer instructions provided with collection kits for specific specimen collection information.
- Testing not approved for patients <14 years of age.
|
| Specimen Labeling |
- Specimen should be labeled with at least two unique patient identifiers and specimen source.
|
| Specimen Processing |
|
| Specimen Storage and Preservation |
- After collection, place patient sample in biohazard bag with absorbent material using care not to touch the foil cap.
- Specimens should be maintained at 2 - 30°C until tested.
|
| Specimen Transportation |
- Specimens must be placed in an individual biohazard bag with absorbent material and should be shipped to the laboratory on the day of collection.
- All specimens for an individual patient may be combined in one bag.
- Store and transport at 2 - 30°C; must arrive within 60 days of collection.
- All infectious substance shipments must conform to U.S. Department of Transportation (DOT) Hazardous Materials Regulations (HMR 49 C.F.R. Parts 171-180).
|
| Specimen Acceptability and Rejection |
- Specimens collected from patients <14 years of age will be rejected.
- If expiration date on tube is prior to collection date, specimen will be rejected.
- Specimens received in improper collection kits will be rejected.
- Specimens received with no swab, two swabs, a cleaning swab, and/or a swab not supplied by Hologic will be rejected.
- Specimens from submitters other than the HIV clinics, or without prior approval will be rejected.
- Specimen is not indentified properly (i.e. information does not match the accompanying order).
|
| Testing Location |
|
This Page Last Updated: September 15, 2025 at 1:20 PM